When good thermal insulation is needed, double log is right choice for wall material. In this kind of construction there is a space between two logs, which can be filled with wood fibre insulation. When k-value for 202 mm thick log wall is 0,53 it is improved to 0,23 with insulated double log wall. (k-value is used to descripe capacity of thermal insulation).
Log
+ Insulation
+ Log
= Thickness
u-value
70
1,28
90
1,05
94
1,02
114/138D
0,87
202
0,53
Log
+ Insulation
+ Panel
= Thickness
u-value
70
50
20
140
0,46
70
100
20
190
0,30
90/94
125
20
235/239
0,24
114/138D
125
20
259/283
0,23
Log
+ Insulation
+ Log
= Thickness
u-value
70
100
70
240
0,26
70
120
70
260
0,23
90/94
100
90/94
280/288
0,24
90/94
120
90/94
300/308
0,21
90/94
140
90/94
320/328
0,19
114/138D
100
114
328/352
0,22
114/138D
140
114
368/392
0,18
sources: EGH Entwicklungsgemeinschaft Holzbau in der Deutschen Gesellschaft für Holzforschung, VTT Rakennus- ja yhdyskuntatekniikka, testausselostus Nro RTE2195/01; Hirsiseinäelementtien lämmönläpäisykertoimien määritykset